3. PIPING CONNECTION
3-1. CAUTION OF PIPING
CAUTION
Keep the permissible length of every piping limitation to prevent a defect or cooling/heating
failure.
z
Piping material
●
Use the designated size ( Diameter & thickness ) of refrigerant pipes.
●
Those pipes purchased locally may contain dust inside. Blow out the dust by dried inert gas when using.
●
To process the branch, do not use T-shaped pipe, which causes a uneven refrigerant flow.
Use the optionally available standard branch kit.
T-tube
Separation tube
Reducer
●
When replacing the unit, never use piping which has been used for previous installations.
Only use the new piping.
z
Piping process stage
●
Be careful to avoid the dust or water falling into the pipe when performing piping process and piping installation.
●
When processing the pipe, make the number of bending portion as few as possible, and the bending radius as
large as possible.
●
If the diameter of the required pipe is different from the branch unit, either cut it out or use the reducer.
z
Brazing
●
While Brazing the pipes, be sure to blow dry nitrogen gas through them.
●
If nitrogen gas is not blown through the pipes while they are being brazed, an oxidized layer may form on the
inside of the pipes. If this occurs, the cooling efficiency may decrease and the air conditioner unit (compressor,
valves, etc.) cause malfunction.
0.02MPa
Pressure hose
Rubber stopper
Bellows valve
Nitrogen gas
●
When brazing the pipes, do not use flux. If the flux is chlorine-based, the pipes will corrode and when the flux
contains fluorine, the refrigerant oil will deteriorate, etc. Using the flux has an adverse affect on the refrigerant
piping system.
●
For brazing materials, use phosphor copper solder that does not require flux.
z
Piping treatment
●
The pipes vibrate, expand, and contract during operation, so if loads are concentrated in one area, it could cause
cracks in the pipes. Provide the pipe supports every 6ft. 6-3/4in to 9ft. 10-1/8in. (2 to 3m)
●
Make sure to insulate the refrigeration pipes separately with ample thickness of heat-resistant polyethylene form
etc. For the connecting portion, apply the enough insulation to avoid any gap.
- (06 - 26) -
SY
ST
EM
DE
SIGN
SY
ST
EM
DE
SIGN
Summary of Contents for Airstage AGUA12TLAV1
Page 1: ...Small VRF system for light commercial and home use DESIGN TECHNICAL MANUAL ...
Page 22: ...1 GENERAL INFORMATION DTV_J2U045E_06 CHAPTER01 2018 03 16 ...
Page 38: ...2 MODEL SELECTION DTV_J2U045E_05 CHAPTER02 2018 03 16 ...
Page 113: ...3 OUTDOOR UNITS DTV_J2U045E_02 CHAPTER03 2016 04 13 ...
Page 122: ...5 WIRING DIAGRAM MODELS AOU36RLAVM AOU48RLAVM 03 08 OUTDOOR UNITS OUTDOOR UNITS ...
Page 123: ... MODELS AOU60RLAVM 03 09 OUTDOOR UNITS OUTDOOR UNITS ...
Page 127: ... SOUND LEVEL CHECK POINT Microphone Airflow 39 3 8 in 1 m 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 130: ...4 INDOOR UNITS DTV_VR2U025E_10 CHAPTER04 2018 01 26 ...
Page 203: ...4 WIRING DIAGRAMS 4 1 COMPACT CASSETTE TYPE MODEL AUUA4TLAV1 04 70 INDOOR UNITS INDOOR UNITS ...
Page 207: ...4 4 MINI DUCT TYPE MODEL ARUL4TLAV1 04 74 INDOOR UNITS INDOOR UNITS ...
Page 211: ... MODELS ARUH72TLAV1 ARUH96TLAV 04 78 INDOOR UNITS INDOOR UNITS ...
Page 215: ...4 11 CEILING TYPE MODELS ABUA30TLAV ABUA36TLAV 04 82 INDOOR UNITS INDOOR UNITS ...
Page 217: ... MODELS ASUA12TLAV1 ASUA14TLAV1 04 84 INDOOR UNITS INDOOR UNITS ...
Page 218: ... MODELS ASUB18TLAV1 ASUB24TLAV1 04 85 INDOOR UNITS INDOOR UNITS ...
Page 219: ... MODELS ASUB30TLAV1 ASUB36TLAV1 04 86 INDOOR UNITS INDOOR UNITS ...
Page 220: ... MODELS ASUA7TLAV ASUA9TLAV ASUA12TLAV ASUA14TLAV 04 87 INDOOR UNITS INDOOR UNITS ...
Page 221: ... MODELS ASUB18TLAV ASUB24TLAV 04 88 INDOOR UNITS INDOOR UNITS ...
Page 361: ...5 CONTROL SYSTEM DTV_VR2U025E_14 CHAPTER05 2018 03 16 ...
Page 563: ...6 SYSTEM DESIGN DTV_J2U045E_05 CHAPTER06 2017 12 26 ...
Page 645: ...7 FUNCTION SETTING DTV_VR2U025E_12 CHAPTER07 2018 03 16 ...
Page 819: ...8 EXTERNAL INPUT OUTPUT DTV_VR2U025E_08 CHAPTER08 2017 12 26 ...
Page 878: ...9 NOTES DTV_VR2U025E_10 CHAPTER09 2017 12 26 ...
Page 894: ...10 OPTIONAL PARTS DTV_VR2U025E_12 CHAPTER10 2018 03 16 ...
Page 935: ...4 5 WIRING DIAGRAMS MODEL UTP RU01AH MODEL UTP RU01BH 10 40 OPTIONAL PARTS OPTIONAL PARTS ...
Page 936: ... MODEL UTP RU01CH 10 41 OPTIONAL PARTS OPTIONAL PARTS ...
Page 937: ... MODEL UTP RU04BH 10 42 OPTIONAL PARTS OPTIONAL PARTS ...