2-15. SIMPLE REMOTE CONTROLLER (UTY-RSRY, UTY-RHRY)
2-15-1. REMOTE CONTROLLER ADDRESS SETTING
CONFIRM THE REMOTE CONTROLLER ADDRESS
1) Select the “15” in Menu 2-F1 Settings.
Then press the “
” button.
2) You can check current allocation of 2-wire
remote controller address (system number and
unit number).
System number
Address automatically
allocated
Unit number
Press the “
” button to return to the Menu 2-F1
item selection screen.
NOTE:
In the case of automatic address settings, do not change the remote controller address for the indoor unit, and keep
it at the initial setting of 0. Addresses will be automatically set when initially starting up this unit.
IF MANUALLY SETTING THE REMOTE CONTROLLER ADDRESS
1) Select the “15” in Menu 2-F1 Settings.
Then press the “
” button.
2) You can check current allocation of 2-wire
remote controller address (system number and
unit number). Set the unit number with the SET
TEMP. “ ” or SET TEMP. “ ” button. System
number cannot be changed.
System number
Address automatically
allocated
Unit number
Press the “
” button to return to the Menu 2-F1
item selection screen.
NOTES:
●
Only set addresses manually when using different numbers for addresses. A remote controller address for the
indoor unit needs to be set. Set the remote controller addresses for the indoor units which are connected using
the same remote controller cable with a range from 1 to 9 and from A (10) to F(15), without any duplicates. (Do
not use “0” for confi guration).) For how to confi gure the remote controller addresses for the indoor unit, refer to
its installation manual.
●
The address for this unit can be set from 1 to 32. However, do not set the same number as that for the remote
controller address of an indoor unit, remote controller, or other unit connected using the same remote controller
cable.
- (07 - 129) -
FUN
C
TI
O
N
SE
TTI
N
G
FUN
C
TI
O
N
SE
TTI
N
G
Summary of Contents for Airstage AGUA12TLAV1
Page 1: ...Small VRF system for light commercial and home use DESIGN TECHNICAL MANUAL ...
Page 22: ...1 GENERAL INFORMATION DTV_J2U045E_06 CHAPTER01 2018 03 16 ...
Page 38: ...2 MODEL SELECTION DTV_J2U045E_05 CHAPTER02 2018 03 16 ...
Page 113: ...3 OUTDOOR UNITS DTV_J2U045E_02 CHAPTER03 2016 04 13 ...
Page 122: ...5 WIRING DIAGRAM MODELS AOU36RLAVM AOU48RLAVM 03 08 OUTDOOR UNITS OUTDOOR UNITS ...
Page 123: ... MODELS AOU60RLAVM 03 09 OUTDOOR UNITS OUTDOOR UNITS ...
Page 127: ... SOUND LEVEL CHECK POINT Microphone Airflow 39 3 8 in 1 m 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 130: ...4 INDOOR UNITS DTV_VR2U025E_10 CHAPTER04 2018 01 26 ...
Page 203: ...4 WIRING DIAGRAMS 4 1 COMPACT CASSETTE TYPE MODEL AUUA4TLAV1 04 70 INDOOR UNITS INDOOR UNITS ...
Page 207: ...4 4 MINI DUCT TYPE MODEL ARUL4TLAV1 04 74 INDOOR UNITS INDOOR UNITS ...
Page 211: ... MODELS ARUH72TLAV1 ARUH96TLAV 04 78 INDOOR UNITS INDOOR UNITS ...
Page 215: ...4 11 CEILING TYPE MODELS ABUA30TLAV ABUA36TLAV 04 82 INDOOR UNITS INDOOR UNITS ...
Page 217: ... MODELS ASUA12TLAV1 ASUA14TLAV1 04 84 INDOOR UNITS INDOOR UNITS ...
Page 218: ... MODELS ASUB18TLAV1 ASUB24TLAV1 04 85 INDOOR UNITS INDOOR UNITS ...
Page 219: ... MODELS ASUB30TLAV1 ASUB36TLAV1 04 86 INDOOR UNITS INDOOR UNITS ...
Page 220: ... MODELS ASUA7TLAV ASUA9TLAV ASUA12TLAV ASUA14TLAV 04 87 INDOOR UNITS INDOOR UNITS ...
Page 221: ... MODELS ASUB18TLAV ASUB24TLAV 04 88 INDOOR UNITS INDOOR UNITS ...
Page 361: ...5 CONTROL SYSTEM DTV_VR2U025E_14 CHAPTER05 2018 03 16 ...
Page 563: ...6 SYSTEM DESIGN DTV_J2U045E_05 CHAPTER06 2017 12 26 ...
Page 645: ...7 FUNCTION SETTING DTV_VR2U025E_12 CHAPTER07 2018 03 16 ...
Page 819: ...8 EXTERNAL INPUT OUTPUT DTV_VR2U025E_08 CHAPTER08 2017 12 26 ...
Page 878: ...9 NOTES DTV_VR2U025E_10 CHAPTER09 2017 12 26 ...
Page 894: ...10 OPTIONAL PARTS DTV_VR2U025E_12 CHAPTER10 2018 03 16 ...
Page 935: ...4 5 WIRING DIAGRAMS MODEL UTP RU01AH MODEL UTP RU01BH 10 40 OPTIONAL PARTS OPTIONAL PARTS ...
Page 936: ... MODEL UTP RU01CH 10 41 OPTIONAL PARTS OPTIONAL PARTS ...
Page 937: ... MODEL UTP RU04BH 10 42 OPTIONAL PARTS OPTIONAL PARTS ...