Name

Gas side joints

Branch List

SYSVRF 
JOINT 
OUT 02 
HP

SYSVRF 
JOINT 
OUT 03 
HP

SYSVRF 
JOINT 
OUT 04 
HP

Appearance And Connection Sketch Of SYSVRF JOINT OUT 02 HP

W

1

W

2

W

1

W

2

W1

W2

W1

W2

W1

1

ID:31.8

0D:34.9

ID:31.8

ID:38.1

ID:34.9

0D:31.8

ID:25.4

0D:31.8

ID:38.1

ID:41.3

ID:31.8

0D:31.8

ID:31.8
ID:25.4

ID:31.8

0D:34.9

ID:31.8

ID:38.1

ID:34.9

0D:31.8

ID:25.4

0D:31.8

0D:34.9

ID:34.9

ID:38.1

ID:34.9

ID:31.8

ID:31.8

0D:31.8

ID:25.4

0D:31.8

ID:38.1

ID:41.3

ID:31.8

0D:31.8

ID:31.8
ID:25.4

ID:31.8
ID:25.4

ID:31.8
ID:25.4

ID:41.3

ID:44.5

ID:31.8

0D:31.8

ID:31.8
ID:25.4

ID:15.9

ID:19.1

ID:15.9

ID:15.9

0D:15.9

ID:12.7

ID:12.7

0D:15.9

0D:25.4

ID:25.4

ID:22.2

ID:22.2

ID:15.9

0D:15.9

ID:15.9

ID:12.7

ID:19.1

ID:22.2

ID:15.9

0D:15.9

ID:15.9

ID:12.7

ID:15.9

ID:15.9

ID:19.1

ID:15.9

0D:15.9

ID:12.7

ID:12.7

0D:15.9

ID:15.9

0D:19.1

ID:19.1

ID:15.9

ID:22.2

ID:19.1

ID:15.9

0D:15.9

ID:12.7

ID:12.7

0D:15.9

ID:19.1

0D:22.2

ID:22.2

ID:19.1

ID:15.9

0D:15.9

ID:15.9

ID:12.7

ID:31.8
ID:25.4

Liquid side joints

Gas balance 

joint 1

Gas balance 

joint 2

Oil balance 

Table.1

Choice

SYSVRF JOINT OUT 02 HP

Branch pipes for outdoor unit

Table.2

SYSVRF JOINT OUT 03 HP

SYSVRF JOINT OUT 04 HP

Size of joint pipes for R410A outdoor unit

Table.3

Field pipe  

Φ

25.4 or 

φ

31.8

(Fix according to machine’s
factory setting pipe size)

Field pipe, the caliber refer to Table.3
If 18

W1+W2

24, i.e. 

Φ

31.8(31.8)

If 26

W1+W2

32,i.e.

Φ

38.1(34.9).

Field pipe  

Φ

25.4 or 

Φ

31.8

(Fix according to machine’s
factory setting pipe size)

Liquid side pipes

W2(Main unit)

Gas pipe joint 

Q1

Gas pipe joint Q3

Gas pipe joint Q4

Gas pipe joint Q2

Field pipe  

Φ

25.4 or 

Φ

31.8

(Fix according to W1 machine’s
factory setting pipe size)

Field elbow bend 

(Machine Accessory)

Flaring connection

Flaring connection

Field pipe 

Φ

15.9

Gas side pipes

W1

W2

Welding

Welding

Field pipe 

Φ

 6.4

Rejoining method for D3 series outdoor unit

Rejoining method for V4/V4+ series outdoor unit

Gas balance pipes 1

Gas balance pipes 2 (V4/D3)

Oil balance pipes

Field pipe, the caliber refer to Table.3
If 18

W1+W2

24, i.e. 

Φ

19.1(15.9)

If 26

W1+W2

32, i.e. 

Φ

22.2(19.1).

Liquid side joint Y3

Field pipe  

Φ

12.7 or 

Φ

15.9

(Fix according to machine’s
factory setting pipe size)

Field pipe  

Φ

12.7 or 

Φ

15.9

(Fix according to machine’s
factory setting pipe size)

Liquid side joint Y1

Liquid side joint Y6

Liquid side joint Y2

Field pipe 

Φ

19.1

Welding

Welding

Installation Precaution

1) Pay attention to the distance of straight horizontal pipe.

a.The straight horizontal pipe’s distance between two adjacent branch 
    pipes should 

0.5m. 

b.The straight horizontal pipe’s distance which outdoor unit connecting
    behind the branch pipe should 

0.5m.

Outdoor unit

Above 0.5m

Outdoor unit

Outdoor unit

Above 0.5m

NOTE

1  When numbers in brackets represent the equivalent length of all liquid pipes < 90m, means the 
     selected pipe size value.
2 It’s advised to use the Max. HP unit as the main unit. See above figure W2 outdoor unit (main unit).
3 The above figure is only available for the models such as D3,V4 and V4+ series with R410A refrigerant 
    when they are paralleled connected.
4 Please select T-style three direct links according to user guide of the external packaging bag; please 
    dumping the redundant T-style three direct links in the accessories and do not use for other purposes.
5 Pipe diameter of outdoor unit :
    V4+:8

10HP, Gas/Liquid side:

Φ

25.4/

Φ

12.7;12

16HP, Gas/Liquid side:

Φ

31.8/

Φ

15.9;

    V4

D3:8

12HP, Gas/Liquid side:

Φ

25.4/

Φ

12.7;14

16HP, Gas/Liquid side:

Φ

31.8/

Φ

15.9.

6 All the pictures in this manual are for explanation purpose only. They may be slightly different from the  
   air conditioner you purchased(depend on model).The actual shape shall prevail.

Y1

Y1

Y6

Y6

Y3

Y3

Y2

Y2

Y1

Y1

Y1

Y1

Y7

Y7

Y1

Y1

Y7

Y7

Y1

Y1

Y8

Y8

Y5

Y5

Y4

Y4

Y6

Y6

Y2

Y2

Y1

Y1

Y6

Y6

Y2

Y2

Q1

Q1

Q3

Q3

Q4

Q4

Q1

Q1

Q1

Q1

Q1

Q1

Q1

Q1

Q1

Q1

Q2

Q2

Q2

Q2

Q2

Q2

Q7

Q7

Q7

Q7

Q5

Q5

Q5

Q5

Q6

Q6

Installation Notices

 

Abandon

Cut from the middle

Cut from the bottom

Cut from the bottom

Fig.1

Fig.2

Fig.3

Fig.4

1)Select the proper branch model according to table2.
2)According to the actual piping size and cut off the needless parts with special tools such as cutter, take the SYSVRF JOINT OUT 02 HP
   gas side for example and the operating steps as follow: 
   a.When selecting model SYSVRF JOINT OUT 02 HP, the actual object as display in Fig.1, and  then suppose that the outlet pipe of  
   the machine is

Φ

31.8, main pipe is

Φ

38.1. As display in Fig.2, cut the standalone connecting pipe Q1 of the branch pipe component.

   b.As display in Fig.2, weld the standalone connecting pipe Q1, Q3 with the U-shape three direct link s Q4; abandon the standalone   
   connecting pipe Q2 because selected pipe size

Φ

31.8 can directly connect with the un-welded side of U-shape three direct links.

   c.As display in Fig.3, weld the branch pipe components with the field pipes. 
3)Particularly notice the followings:
   a.When the actual pipe size matches with the un-welded side of U-shape three direct links, weld the pipe with the U-shape three  
   direct links. 
b.For the connecting pipes Q3 and Q7, if they need to be cut, please cut in the bottom of the flaring as display in Fig. 4.

Q1

Q1

Q2

Q2

Q1

Q1

Q2

Q2

Q1

Q1

Q7

Q7

Q4

Q4

Q4

Q4

Q3

Q3

Q3

Q3

Q4

Q4

Q3

Q3

Thank you very much for purchasing our air conditioner,  Before using your air conditioner , please read this manual carefully and keep it for future reference.

OUTDOOR UNIT BRANCH PIPE INSTALLATION MANUAL

2

3

4

Incision

Cut off the part 

from middle site

Branch 

pipe

Field pipe

Connection 

      part

Keep the cutting direction 

and the copper pipe in a 

vertical position 

Heat insulation
      material

(2 sets)

(4 sets)

(6 sets)

Heat insulation

1) Example of connected branch. 

Be sure to insulate the brahches 
against heat

Field pipe

Field pipe

Branch (supplied)

Field pipe

heat insulation material(supplied)

Tape

Field piping heat 
insulation material

2) Use the supplied heat insulation  
    material to insulate the branches 
    against heat.

3) Apply the heat insulation material 
    and seal all connections with tape.

Horizontally Placing Branch Pipe

B

A

Direction A

Direction B

 ±10°

 ±10°

 ±10°

A horizontally incline angle should not larger than 10°.   

Adhesive paper(tear off before pasting)

Model

Gas side

Liquid side

Φ

22.2

Φ

22.2

Φ

25.4

Φ

28.6

Φ

28.6

Φ

28.6

Φ

31.8

Φ

41.2

Φ

9.53

Φ

9.53

Φ

12.7

Φ

12.7

Φ

15.9

Φ

15.9

Φ

19.1

Φ

22.2

 When the equivalent length of all liquid 
pipes < 90m, the size of main pipe(mm)

8HP

10HP

12~14HP

  16HP

18~22HP

24HP

26~34HP

52~66HP

Φ

38.1

Φ

19.1

36~50HP

Gas side

Liquid side

Φ

22.2

Φ

25.4

Φ

28.6

Φ

31.8

Φ

31.8

Φ

31.8

Φ

38.1

Φ

44.5

Φ

12.7

Φ

12.7

Φ

15.9

Φ

15.9

Φ

19.1

Φ

19.1

Φ

22.2

Φ

25.4

 When the equivalent length of all liquid 
pipes 

 90m, the size of main pipe(mm)

Φ

38.1

Φ

22.2

Φ

44.5

Φ

25.4

68~88HP

Φ

54.0

Φ

25.4

 Quantity of 
outdoor units

Branch pipe