186
including the additional ramp up/down time. Display functions and markers are available for advanced
analysis. Overlays of slot centers and burst time regions are shown. See Figure 2.2.7.9.1.3-5.
Note: See the transmitter power envelope standard: TIA-102.CCAA 2.2.17.3 TDMA Method of
Measurement
Figure 2.2.7.9.1.3-5 Power Profile Frame
Select View (Power Profile submenu)
Select the slot(s) to view. Although slots are alternating 30 milliseconds, the profile for a slot is 30.4 ms,
divided into three regions for ramp-up (1.2 ms), burst (28.0 ms), and ramp-down (1.2 ms).
Frame – Horizontal axis -0.2 ms to 60.2 ms with slots from 0 to 30 and 30 to 60 ms. See Figure
2.2.7.9.1.3-5.
Slot 1 – Horizontal axis -0.2 ms to 30.2 ms with slot from 0 to 30 ms.
Slot 2 – Horizontal axis 29.8 ms to 60.2 ms with slot from 30 to 60 ms.
Note: Ramp up/down times for a slot overlap the adjacent slots by 0.2 milliseconds.
Summary of Contents for R8100 SERIES
Page 19: ...19 Figure 2 1 2 Left and Right Sides of the R8100...
Page 164: ...164 Figure 2 2 7 7 5 Power Profile Frame with Markers...
Page 224: ...224 Figure 3 2 9 6 1 Submenu after pressing Options soft key in the Settings menu...
Page 243: ...243 PTC Test in Monitor Mode Eye Diagram Display...
Page 244: ...244 Power Profile Display Linear and Circular Constellation Displays...
Page 245: ...245 Symbol Distribution Plot...