45
The last page of the Audio Zone submenu also contains the baseband filter settings for the R8100 Monitor
mode.
Note: Audio Zone submenu screens display common settings along with menu choices that change to
reflect the Format (signal type) chosen for the audio synthesizer. Different submenu screens and settings
appear when other encoding types such as DPL, A/B Sequence, or 5/6 Tone are selected with the Format
soft key. The following sections will first describe the common settings, followed by the alternate settings
specific to each encoding format.
Figure 3.2.4.1-1 Audio Zone submenu in Monitor mode
2.2.3.2
Common Audio Settings for the Audio Zone submenu
Fixed 1kHz Level
Adjusts the fixed 1 kHz tone generator amplitude from 0 to 8V Peak in a data entry window using the
arrow keys, keypad, or spin knob. Pressing Enter completes the change and Esc cancels the entry.