![FLIR Ranger HRC MS Operator'S Manual Download Page 158](http://html1.mh-extra.com/html/flir/ranger-hrc-ms/ranger-hrc-ms_operators-manual_2306230158.webp)
Ranger HRC™ operator´s manual – System operation
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
11.4.2.5 Editing autoscan points settings and Moving autoscan points
This section describes how the speed and dwell settings of the autoscan
points are edited and how the position of an autoscan point is moved.
Editing settings and Moving autoscan points
Step
Action
1
Do the necessary settings according to section 11.4.2.1.
2
Press the
SCN
button to enter AUTOSCAN mode.
3
Press the
FCN
button to enter PROG POSITION mode.
4
Use the
and
buttons to go to the desired autoscan point.
5 a
To edit the autoscan point, press the
FCN
button to open the
Edit pos #
dialog box.
5 b
To move the autoscan point, press and hold down the
FCN
button and use the joystick to
move the system to the new desired position.
Use the JCU to make the desired adjustments of field-of-view and focus; see section
11.4.2.2.
Press the
FCN
button to register and save the position and the field-of-view, focus and
zoom settings. The
Edit pos #
dialog box is displayed.
6
Select the Speed and Dwell settings of the autoscan point, see section 11.4.2.3.
7
Repeat step 46 to edit next autoscan point or move next autoscan point.
8
Press the CANCEL button to exit the PROG POSITION mode. The
Quit programming
dialog box will appear. Select
Yes
to exit.
9
To save the new autoscan list, see section 11.4.2.7 and section 11.4.2.8.
11.4.2.6 Route sequence
This section describes how the route sequence is managed.
The route sequence defines the order in which the autoscan points shall
be scanned.
The order of the autoscan points in the currently active autoscan list can
be changed and autoscan points can be inactivated. Inactivated autoscan
points are still available and can be activated again if needed.