Ranger HRC™ operator´s manual – System operation
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
11.4.2 Autoscan lists
Autoscan lists can be created, saved, reloaded and deleted. Autoscan
points can be edited and moved.
The procedures for managing autoscan lists apply to the currently active
autoscan list. To be able to manage a stored autoscan list, the stored list
must first be recalled. Please refer to section 11.4.2.7.
11.4.2.1 Preparations
The features for programming of autoscan points and management of
autoscan lists are available in the System Software menu system when IR
is selected (not when TV is selected).
Selecting IR Camera
1
Ensure that IR is selected. If not, press the
TV/IR
button to select IR.
For full functionality of the Joystick Control Unit (JCU) when program-
ming autoscan points and managing autoscan lists, the Original setting of
the JCU must be selected.
Original setting
1
Press the ENTER button to enter MENU mode.
2
Select
Maintenance…
from the
Setup
menu and press the ENTER button. The
Setup
– Maintenance
dialog box is displayed.
3
Select
MMI control mode
.
4
Use the LEFT/RIGHT buttons to select
Original
.
Press the ENTER button to confirm and to exit MENU mode.