Installation Instructions
8.7.08
Panda PMS 8.000 NE - 42 NE Manual.R04 - Capture D: Installation Instructions Seite 87
D.4.4 Scheme for Freshwater Circuit at Two Circuit Cooling System
Fig. D-1: Scheme for Freshwater Circuit at Two Circuit Cooling System
D.4.5 Pressure Test for Controlling the Cooling Water Circuit
Check if a temperature difference exists between cooling water in-flow and cooling water return
flow by use of the hand.
Feel the cooling water in-flow line at the internal cooling water pump.
Feel the cooling water return pipe either at the outlet of the water-cooled exhaust elbow union or
at the side, where this pipe exits at the heat exchanger.
The temperature difference between in-flow and return should be approx 10 degrees.
1. Expansion Tank
2. Exhaust Manifold
3. Thermostat Housing
4. Freshwater pump
5. Heat Exchanger
6. Cooling Water Connection Block