![Fischer Panda Panda PMS-HD 12-4KU Manual Download Page 21](http://html1.mh-extra.com/html/fischer-panda/panda-pms-hd-12-4ku/panda-pms-hd-12-4ku_manual_2294313021.webp)
The Panda Generator
Panda_12-4KU_HD-PMS_eng - Chapter A: The Panda Generator Page 21
A.3 Details of functional units
A.3.1 Remote control panel - see remote control panel datasheet
The remote control panel is necessary to control the generator and to evaluate the motor/genera-
tor properties. The generators will automatically cutout if it does not run as required. The genera-
tor may not be run without the remote control panel.
A.3.2 Components of Cooling System (Raw water)
Raw water intake
The diagram shows the supply pipes for
the generator. The connection neck for
the raw water connection is shown on the
left hand side. The cross-section of the
intake pipe should be nominally larger
than the generator connection.
A.3.3 Raw water intake
Raw water impeller pump
The raw water pump is fitted with a rubber
impeller. This pump is self-inductive. If, for
example, you forget to open the sea
valve, then you must expect the impeller
to be destroyed after a short period of
time. It is recommended to store several
impellers on board as spare parts.
Fig. A.3.3-1: Raw water inpeller pump