![Fischer Panda Panda PMS-HD 12-4KU Manual Download Page 28](http://html1.mh-extra.com/html/fischer-panda/panda-pms-hd-12-4ku/panda-pms-hd-12-4ku_manual_2294313028.webp)
The Panda Generator
Page 28 Panda_12-4KU_HD-PMS_eng - Chapter A: The Panda Generator
Fuel solenoid valve
The fuel solenoid valve opens automati-
cally if „START“ is pressed on the remote
control panel“. The solenoid closes, if the
generator is switched to „OFF“ position. It
takes a few seconds before the generator
stops. If the generator does not start or
does not run smoothly (i.e. stutters), or
does not attain full speed, then the cause is
fore-mostly the solenoid.
1) Fuel solenoid valve
2) Ventilation screw solenoid valve
3) Magnetic coil
Fig. A.3.5-5: Fuel solenoid valve
Injection nozzles
If the engine does not start after the venti-
lation, the fuel injection lines must be de-
aerated individually.
Fig. A.3.5-6: Injection nozzles
Glow plugs
The glow plugs serve the pre-chamber for
the heating with cold start. The heat-treat
fixture must be operated, if the tempera-
ture of the generator is under 16°C. This
is practically with each start the case. The
heat-treat fixture may be held down also
during start and favoured the starting pro-
cedure.
Fig. A.3.5-7: Glow plugs
3
1
2