Maintenance Instructions
Seite 72 Panda PMS 8.000 NE - 42 NE Manual.R04 - Kapitel C: Maintenance Instructions
8.7.08
Remove the cover of the seawater pump
by loosen the 4 wing screws from the hou-
sing.
Fig. C.6.1-3: Cover Seawater Pump
2. Remove the impeller from the shaft by
means of multi grip pliers..
3. Mark the impeller, to make sure that it
is in the correct position when re-instal-
lation is carried out.
Fig. C.6.1-4: Impeller
4. Check the impeller for damage and
replace it if necessary.
5. The impeller should have been lubrica-
ted with glycerine or with a non-mineral
oil based lubricated e.g. silicone spray,
before re-insertion into the housing.
Attention: This is very important,
because the impeller can quickly be
damaged.
Fig. C.6.1-5: Impeller