MOTOR STOPS BY ITSELF
Cause
Solution
Lack of fuel.
Check fuel supply system.
Excess heat in cooling system (thermo switch tripped)-
lack of cooling water. Is indicated on the remote control
panel.
Check cooling water system flow: water pump, inlet
water filter, extra heat exchanger coolant flow.
Lack of oil (oil pressure sensor tripped). Is indicated on
the remote control panel.
Check oil-level and if necessary top up.
Check motor's oil-pressure and have repaired by
Kubota-Service if necessary.
SOOTY, BLACK EXHAUST
Cause
Solution
Generator is overloaded.
Check electrical load and switch off unnecessary load.
Insufficient intake air.
Check intake air filter; clean if necessary.
Fuel injector faulty.
Replace injector.
Valve clearance incorrect.
Readjust valve clearance to correct value (refer to
Farymann-manual).
Poor fuel quality.
Use better quality diesel (recommended: 2-D Diesel).
Poor combustion.
Incorrect AFR (air/fuel ratio) due to motor timing adjust-
ment. Have motor serviced by Kubota.
GENERATOR MUST BE SHUT OFF IMMEDIATELY IF:
Cause
Solution
- motor rpm suddenly rises or drops
- unusual noise comes from genset
- exhaust colour suddenly becomes dark
- leakage in the cooling water system.
Refer to respective section of manual and if necessary,
have repaired by Kubota-Service, or Panda represen-
tative.