D.8.3 AC Control Box with VCS and ASB
The required capacitors for the excitation of the generator are located in the AC-Control box, as
well as the electronic control for voltage/speed regulation (VCS) and the starting current re-
inforcement (ASB). The AC-Control box must be connected by electrical wires (high voltage and
low-voltage) to the generator.
The front panel must always be closed, since the AC-Control box produces 400 V during opera-
tion.
The AC-Control box must be electrically connected to the generator (high and low
voltage).
Danger - High voltage
ATTENTION! Before working on the System read the "Section Safety Instruc-
tions in this Manual".
Fig. D.8.3-1: Opened AC Control Box
From Panda 30 upwards
Fig. D.8.3-2: Opened AC Control Box from Panda 30 upwards
1
3
2
1. Inlet VCS-connection (X1)
2. Inlet measuring voltage (X3)
3. Excitation cable to generator
(X4)