![Fischer Panda Panda PMS-HD 12-4KU Manual Download Page 24](http://html1.mh-extra.com/html/fischer-panda/panda-pms-hd-12-4ku/panda-pms-hd-12-4ku_manual_2294313024.webp)
The Panda Generator
Page 24 Panda_12-4KU_HD-PMS_eng - Chapter A: The Panda Generator
Freshwater backflow
The cooling water is fed to the heat
exchanger from the water-cooled manifold
by means of the pipe shown in the dia-
gram.
Fig. A.3.4-4: Freshwater backflow
Heat exchanger
Separates the raw water system from the
freshwater system.
Fig. A.3.4-5: Heat exchanger
Cooling water connection block
The cooling water is fed to the generator
and drained via the cooling water connec-
tion block. The cooling water connection
block consists of an aluminium alloy,
which can behave like a sacrificial anode.
Fig. A.3.4-6: Cooling water connection block