![Fischer Panda Panda PMS-HD 12-4KU Manual Download Page 29](http://html1.mh-extra.com/html/fischer-panda/panda-pms-hd-12-4ku/panda-pms-hd-12-4ku_manual_2294313029.webp)
The Panda Generator
Panda_12-4KU_HD-PMS_eng - Chapter A: The Panda Generator Page 29
Stop solenoid for engine stop
Some model are additional equipped with
an stop solenoid. The generator is stopped
by the co-operation of the stop solenoid
immediately after switching off. The adjust-
ment of the stop solenoid must always be
checked, in order to be sure that the stop
lever can move also during the operation
freely and is not under pre-stressing.
Fig. A.3.5-8: Stop solenoid
A.3.6 Components of combustion air
Air suction openings at the sound cover
The sound cover is provided at the back
side with drillings, through which the com-
bustion air can influx.
It must be consistently paid attention that
the generator is installed in such a way
that from down no water can arrive into
the proximity of these air openings.
Fig. A.3.6-1: Combustion air intake
Air suction housing
If the cover is removed, the inside of the
air suction housing becomes visible. In
these air suction housings is a filter ele-
ment. At the marine version the filter is
normally not changed. It should be chek-
ked once in a while.
Fig. A.3.6-2: Air suction housing