D.2 Generator Connections
Connect all electrical wires within the capsule tightly to the motor and the generator. This is also
the case for fuel lines and cooling water lines.
The electrical connections MUST be carried out according to the respective valid regulati-
ons. This also concerns used cable materials. The cable supplied is meant for laying "pro-
tected" (i.e. in pipe) at a temperature up to a max of. 70 °C (160 °F). The on-board circuit
must also be fitted with all essential fuses.
ATTENTION! Before working (installation) on the System read the section
„Safety Instructions“ in this Manual.
Fig. D.2-1: Generator Connections
1
2
3
4
5
6
7
8
9
10
11
1.
raw water inlet
2.
Fuel supply (in)
3.
Fuel return line (out)
4.
Electrical cable for external fuel pump
5.
Motor oil drain hose
6.
Electrical cable to remote control panel
7.
VCS cable to AC-Control box
8.
Generator output cable to AC-Control box
9.
Generator AC-output cable
10. Generator Starter-battery negative (-)
11. Generator Starter-battery positive (+)