1. Pneumatic interfaces
1−15
Festo P.BE−CPX−EA−E N en 0705f
1.5
Instructions on commissioning
Midi/Maxi, CPA or
VTSA pneumatics
The reaction of the pneumatic interface for Midi/Maxi, CPA
or VTSA pneumatics can be parametrized. The table below
gives an overview of the parameters for the pneumatic
interfaces.
With the MPA pneumatics, parametrizing takes place via the
individual MPA pneumatic modules (module−orientated, see
chapter 2).
Further information on parametrizing can be found in the
system manual or in the manual for the field bus node.
Please note
Activate the wire−fracture monitoring only for outputs
which also have a valve solenoid coil.
If the wire−fracture monitoring is activated for an output
which does not have a valve solenoid coil, the CPX terminal
will register the fault Wire fracture" when it is switched
on, due to the valve solenoid coil being incorrectly regis
tered as defective.