1. Pneumatic interfaces
1−11
Festo P.BE−CPX−EA−E N en 0705f
3. Set the DIL switch elements in accordance with the follow
ing table. Use a suitable tool, e.g. a small screwdriver, for
setting the DIL switches.
1
Printed circuit
board
2
Fault LED
3
DIL switches for
configuring the
pneumatics
1
2
3
Fig.1/4:
DIL switches on the pneumatic interface (here for CPA pneumatics)
The DIL switch contains 8 switch elements. These switch
elements are numbered from 1...8. The positions OPEN (CPA,
VTSA/ISO) or ON (Midi/Maxi) are marked.
Rules for setting
If the number of valve solenoid coils fitted is less than the
number of output addresses set with the DIL switch, the
superfluous addresses will be reserved for later exten
sions (if the maximum number of valves is fitted, output
addresses will then remain unused).
Modifications to the configuration will not become
effective until the operating voltage is switched on again.
8 further output addresses per switch element will be
assigned for valves in the address range.
The setting of the highest−value DIL switch in the ON
(closed) position is decisive for the assigned address
range.
Summary of Contents for VMPA...-FB-EPL Series
Page 2: ......
Page 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Page 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Page 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Page 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Page 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Page 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Page 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Page 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...