1. Pneumatic interfaces
1−22
Festo P.BE−CPX−EA−E N en 0705f
Fault LED
Midi/Maxi, CPA or
VTSA pneumatics
The red fault LED of these pneumatic interfaces indicates
the faults of the pneumatic interface depending on the
parametrization.
Fault LED
(red)
Sequence
Status
Fault
number
Fault
treatment
LED is out
ON
OFF
Faultless operation
None
LED lights up
ON
OFF
Fault in load voltage for valves
Load voltage for the valves (V
VAL
)
missing or too low.
5
See section
1.6.1, Tab.1/9.
LED lights up
Fault short circuit at valve
Short circuit/overload at valve
11
Wire fracture fault
Monitoring the residual current of
the valve solenoid coils (open load,
only active with 0−signal).
Only relevant for CPA or VTSA pneu
matics.
13
Tab.1/10:
Fault LED for pneumatic interfaces Midi/Maxi, CPA or VTSA pneumatics
The fault indicated by the red fault LED is transmitted by the
pneumatic interface to the field bus node (unless parame
trized otherwise).
Status LEDs of the valve solenoid coils
The yellow status LEDs on the valve solenoid coils indicate
the status of the relevant output (see appropriate pneumatics
manual).
Summary of Contents for VMPA...-FB-EPL Series
Page 2: ......
Page 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Page 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Page 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Page 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Page 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Page 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Page 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Page 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...