1. Pneumatic interfaces
1−10
Festo P.BE−CPX−EA−E N en 0705f
Caution
Modules may be damaged if they are not handled
correctly.
·
Do not touch the electrical contacts of the modules.
·
Observe the regulations for handling electrostatically
sensitive components.
·
Discharge yourself electrostatically before fitting or re
moving components in order to protect the components
against discharges of static electricity.
Please note
Handle all modules and components of the CPX terminal
with great care. Please note especially the following:
·
Screws must be fitted accurately (otherwise threads will
be damaged).
Screws must be fastened at first only by hand. Place the
screws so that the self−cutting threads are used.
·
The specified torques must be observed.
·
Screw connections must be fitted free of offset and
mechanical tension.
·
Check the seals for damage (IP65).
·
Connecting surfaces must be clean (to ensure sealing
effect, avoid leakage and contact faults).
The screw connection between the cover and the lower
part of the CPA pneumatic interface is designed for at least
10 fitting/removal cycles.
Removing the cover
1. Loosen the screws in the cover with a TORX screwdriver
size T10.
2. Lift the cover up carefully.
Summary of Contents for VMPA...-FB-EPL Series
Page 2: ......
Page 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Page 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Page 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Page 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Page 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Page 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Page 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Page 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...