3. Overview and connecting technology I/O modules
3−28
Festo P.BE−CPX−EA−EN en 0705f
3.3.2
Fitting the screening/shield plates
A screening plate type CPX−AB−S−4−12 can be fitted on sub−
bases CPX−AB−4−M12x5−5POL and CPX−AB−4−M12−8POL.
The sub−base must be removed before the terminal is fitted
or dismantled.
Fitting
Fit the screening plate as follows (see Fig.3/9):
1. Dismantle the sub−base (see section 3.3.1).
2. Snap the spring clips of the screening/shield plate from
above into the appropriate recesses on the dismantled
sub−base.
3. Fit the sub−base.
Instructions on earthing the screening/shield plate can be
found in section 3.2.3.
Dismantling
The screening/shield plate must be removed in the opposite
sequence to the fitting procedure.