6. Multi I/O modules
6−9
Festo P.BE−CPX−EA−EN en 0705f
Sockets X1 to X4 are designed for connecting cylinder−valve
combinations type DNCV with connecting cable type
KM12−8GD8GS−2−PU.
Please note
Inputs Ix+4 and Ix+6 are provided both at pin 7 of sockets
X1 and X2 as well as at pin 2 of sockets X3 and X4.
The cylinder−valve combination type DNCV
with
diagnostic
module
and
activated diagnostic output supplies an in
verted diagnostic signal (1−signal = no fault) at pin7.
When therefore cylinder−valve combinations type DNCV
with
diagnostic module
and
activated diagnostic output
are connected to sockets X1 and X2, pin 2 at sockets X3
and X4 cannot be used.
Summary of Contents for VMPA...-FB-EPL Series
Page 2: ......
Page 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Page 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Page 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Page 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Page 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Page 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Page 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Page 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...