5. Output modules
5−22
Festo P.BE−CPX−EA−EN en 0705f
5.4
Instructions on commissioning
The reaction of the I/O modules can be parametrized.
The table below gives an overview of the parameters.
Further information on parametrizing can be found in
the system manual or in the manual for the field bus node.
5.4.1
Parameters of the output modules types CPX−4DA, CPX−8DA and
CPX−8DA−H
Module parameters: Monitoring the CPX module
Function no.
4828 + m * 64 + 0
m = module number (0 ... 47)
Description
Monitoring of the possible faults can be activated or deactivated (suppressed)
for each module independently. Active monitoring causes the following:
The fault is:
sent to the CPX field bus node
displayed by the module common error LED.
Bit
1
2
Monitoring
Description
Short circuit/overload at the outputs (SCO)
Undervoltage at outputs (V
OUT
)
[Monitor]
[Monitor SCO]
[Monitor Vout]
Values
1 = active (presetting)
0 = inactive
[Active]
[Inactive]
Note
Monitoring can also be set for the complete CPX terminal (see System para
meter monitoring").
Tab.5/18:
Monitoring the CPX module
Summary of Contents for VMPA...-FB-EPL Series
Page 2: ......
Page 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Page 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Page 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Page 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Page 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Page 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Page 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Page 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...