Festo — MSE6-E2M — 2022-08d
Commissioning
33
Plugs
Pin
Function
Description
M18
1
24 V DC U
El/Sen
Operating voltage supply for electronics and
sensors
2
24 V DC U
Out/A
Load voltage supply for actuators and valves
3
0 V
U
El/Sen
U
Out/A
Earth for electronics and sensors and actua-
tors and valves
4
FE
–
Functional earth
Tab. 17: System supply pin allocation M18 plug
8
Commissioning
8.1
Safety
The product is equipped with a pneumatically-piloted shut-off valve. If there is pressure at pneumatic
connection 1, the shut-off valve is open in the normal position.
With preset parameters and applied input pressure P1 the shut-off valve automatically switches to the
pressurise state in the following cases:
–
Switch-off of the operating voltage or the load voltage
–
Interruption of the network communication with correspondingly set system parameters
–
Stopping of the higher-order controller (see manufacturer's specifications), e.g. in the case of
transmission of control programs, parameters, configuration data
If the shut-off valve was previously closed and the system was exhausted, the system is suddenly
pressurised. Take this response into account in the design of the system.
8.2
Commissioning the product
In order to avoid connection and addressing errors, you should carry out the commissioning steps as
follows.