Avoiding parameterisation errors
To avoid errors during parameterisation, the sequence described in the example below must be
observed when changing the units parameter and the upper limit value x parameter.
Example: sequence for initial or start-up parameterisation, energy efficiency module in delivery
status, parameterisation error monitoring active
1. Set the desired unit in the units module parameter.
2. Set the upper and lower limit values in the pressure limit values module parameter.
Example: sequence for modifying the parameterisation
1. Deactivate the monitoring for parameterisation errors in the monitoring module parameter.
2. Parameterise the energy efficiency module as follows:
–
Set the upper limit value in the limit values module parameter to 32767.
–
Set the desired unit in the unit pressure module parameter.
–
Set upper and lower limit values in the limit values module parameter if required.
3. Activate the monitoring for parameterisation errors in the monitoring module parameter.
9.3
Overview of module parameters
The module parameters are distinguished as follows:
–
Modifiable module parameters
–
Read-only module parameters
Detailed information on parameterisation
The functions of the energy efficiency module are identified as follows in the following overview of the
modifiable module parameters:
Identification
Function
Q
Flow measurement
V
Consumption measurement
P2
Pressure measurement
DP2
Pressure change
LOCK
Blocking function
Tab. 42: Identification of the functions in the overview of the modifiable module parameters
Function number
Changeable module parameters
Function
m = module number 1
Q
V
P2
DP2
LOCK
4828
+ m * 64 + 0
Pm.0: monitoring
Bit 2: undervoltage U
Out/A
–
–
–
–
n
Bit 6: limit values
n
–
n
n
–
Bit 7: Parameter error
n
n
n
n