Festo — MSE6-E2M — 2022-08d
Technical data
81
MSE6-E2M
Accuracy of flow rate
± 3% of the measured value, + 0.3% FS
Repetition accuracy, zero
point
[%FS]
± 0.2
Repetition accuracy, margin
[%FS]
± 0.8
Temperature coefficient,
margin
[%FS/K]
Typically ± 0.1
Pressure-dependent margin
[%FS/
MPa]
± 5
[%FS/bar] ± 0.5
[%FS/psi] ± 0.0345
Shut-off valve
Switch-on pressure
[MPa]
£
0.4
[bar]
£
4
[psi]
£
58.02
Switch-off pressure
[MPa]
£
0.1
[bar]
£
1
[psi]
£
14.5
Residual pressure
[MPa]
£
0.1
[bar]
£
1
[psi]
£
14.5
1) % FS = percentage of the measurement value range end value, full scale
2) Typical accuracy under nominal conditions 0.6 MPa (6 bar, 87.02 psi), 23 °C and horizontal mounting position
Tab. 68: Technical data, pneumatic
12.3
Technical data, electrical
MSE6-E2M
Operating voltage supply for electronics and sensors, U
El/Sen
Nominal voltage
[V DC]
24 ± 25 %
Current consumption
[mA]
Max. 300 at 24 V
Cable length
[m]
Max. 30
Load voltage supply for actuator technology, U
Out/A
Nominal voltage
[V DC]
24 – 25 %/
+
10 %
Current consumption
[mA]
Max. 100