![Festo CMMP-AS-***-M3 Series Description Download Page 99](http://html1.mh-extra.com/html/festo/cmmp-as-m3-series/cmmp-as-m3-series_description_2283123099.webp)
A
Diagnostic messages
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
99
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
14-7
–
Identification not
possible
Angle encoder at a stand-
still.
•
Ensure sufficient inter-
mediate circuit
voltage.
•
Encoder cable connec-
ted to the right motor?
•
Motor blocked, e.g.
holding brake does
not release?
PS off
14-8
–
Invalid number of
pairs of poles
The calculated number of
pole pairs lies outside the
parameterisable range.
•
Compare result with
the technical data
specifications for the
motor.
•
Check the paramet-
rised number of lines.
PS off
15-2
–
Counter underrun
Internal firmware error.
Internal correction factors
could not be calculated.
•
Check the setting of
the factor group for
extreme values and
change if necessary.
PS off
15-0
6185
h
Division by 0
Internal firmware error.
Division by 0 when using
the Math Library.
•
Load factory settings.
•
Check the firmware to
make sure that re-
leased firmware has
been loaded.
PS off
15-1
6186
h
Mathematical
overflow during
division
Internal firmware error.
Overflow when using the
Math Library.
•
Load factory settings.
•
Check the firmware to
make sure that re-
leased firmware has
been loaded.
PS off
16-0
6181
h
Error in program
execution
Internal firmware error.
Error during program exe-
cution. Illegal CPU com-
mand found in the pro-
gram sequence.
•
In case of repetition,
load firmware again. If
the error occurs re-
peatedly, the hard-
ware is defective.
PS off
16-1
6182
h
Illegal interrupt
Error during program exe-
cution. An unused IRQ
vector was used by the
CPU.
•
In case of repetition,
load firmware again. If
the error occurs re-
peatedly, the hard-
ware is defective.
PS off
Summary of Contents for CMMP-AS-***-M3 Series