Service functions and diagnostic messages
76
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
8
Service functions and diagnostic messages
8.1
Protective and service functions
8.1.1
Overview
The motor controller CMMP-AS-...-M3 has a complex array of sensors that monitor the controller sec-
tion, power output stage, motor and external communication to ensure that they function excellently.
All diagnostic events which occur are saved in the internal diagnostic memory. The diagnostic memory
in the motor controller has a two-tier architecture:
–
All messages since the motor controller was last switched on are saved in the temporary memory
(these are lost in the event of a power failure).
–
The messages are permanently saved in the permanent memory of the family CMMP-AS-...-M3 (se-
cure in the event of a power failure). This memory consists of 2 segments that are filled one after
the other. When both segments are full, the older segment is automatically cleared. This means that
a sort of ring memory is available for the permanently saved messages.
Most errors cause the controller section to switch off the motor controller and the power end stage.
The motor controller can only be switched on again when the error has been eliminated and then ac-
knowledged.
For some of the diagnostic messages, the behaviour of the motor controller can be parameterised.
Possible reactions:
–
PS off
Switch off power section immediately
–
MCStop
Stop with maximum peak current
–
QStop
Quick stop with the deceleration specified on the “Axis” (FCT) page
–
Warn
Output of a warning
–
Ignore
Ignore diagnostic message
A complex system of sensors and numerous monitoring functions ensure operational reliability:
–
Measurement of the motor temperature
–
Measurement of the power output stage temperature
–
Earth fault detection (PE)
–
Detection of short-circuits between two motor phases
–
Detection of overvoltages in the intermediate circuit
–
Detection of faults in the internal voltage supply
–
Collapse of supply voltage
8.1.2
Phases and mains failure detection with 3-phase motor controllers
The motor controller CMMP-AS-...-M3 detects a phase failure in three-phase operation (phase failure
detection) or failure of several phases (network failure detection) of the mains supply at the device.
8.1.3
Overload current and short-circuit monitoring
Overload current and short-circuit monitoring detects short circuits between two motor phases and
short circuits at the motor output terminals against the positive and negative reference potential of the
intermediate circuit and against PE. If the error control detects overload current, the power output
stage shuts down immediately, guaranteeing protection against short circuits.