A
Diagnostic messages
102
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
25-1
6081
h
Device type not
supported
Device coding valid, but
not supported by the
loaded firmware
•
Load up-to-date firm-
ware.
•
If newer firmware is
not available, the
problem may be a
hardware defect.
Send motor controller
to the manufacturer.
PS off
25-2
6082
h
Technology mod-
ule: hardware re-
vision not sup-
ported
The controller's hardware
version is not supported
by the loaded firmware.
•
Check the firmware
version; update the
firmware to a more re-
cent version if neces-
sary.
PS off
25-3
6083
h
Device function
restricted!
Device is not unlocked for
this function
Device is not unlocked for
the desired functionality
and may need to be un-
locked by the manufac-
turer. The device must be
sent to Festo for this.
PS off
26-7
–
Faulty data tables
(CAM)
Data for the cam disk is
corrupted.
•
Load factory settings
•
Reload the parameter
set if necessary.
If the error persists, con-
tact Technical Support.
PS off
26-0
5580
h
Missing user
parameter set
No valid user parameter
record in the flash
memory
•
Load factory settings.
If the error remains, the
hardware may be defect-
ive.
PS off
26-1
5581
h
Checksum error
Checksum error of a para-
meter set
•
Load factory settings.
If the error remains, the
hardware may be defect-
ive.
PS off
Summary of Contents for CMMP-AS-***-M3 Series