Diagnostic messages
126
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
90-2
5080
h
Error at FPGA
boot-up
The FPGA cannot be
booted. The FPGA is
booted serially when the
device is started, but in
this case it could not be
loaded with data or it re-
ported a checksum error.
Switch on the device
again (24 V). If the error
appears again, the hard-
ware is faulty.
PS off
90-3
5080
h
Error at SD-ADU
start
SD-ADUs cannot be star-
ted. One or more SD-
ADUs are not supplying
any serial data.
Switch on the device
again (24 V). If the error
appears again, the hard-
ware is faulty.
PS off
90-4
5080
h
SD-ADU syn-
chronisation error
after start
SD-ADU not synchronous
after starting. During op-
eration, the SD-ADUs for
the resolver signals con-
tinue running with strict
synchronisation once
they have been initially
started synchronously.
The SD-ADUs could not
be started at the same
time during that initial
start phase.
Switch on the device
again (24 V). If the error
appears again, the hard-
ware is faulty.
PS off
90-5
5080
h
SD-ADU not syn-
chronous
SD-ADU not synchronous
after starting. During op-
eration, the SD-ADUs for
the resolver signal contin-
ue running with strict syn-
chronisation once they
have been initially started
synchronously. This is
checked continually dur-
ing operation and an error
may be triggered.
Severe EMC interference
could theoretically also
cause this effect. Switch
on the device again
(24 V). If the error ap-
pears again, the hard-
ware is faulty (almost cer-
tainly one of the three
SD-ADUs).
PS off
90-6
5080
h
IRQ0 (current
regulator): trigger
error
The output stage is not
triggering the software
IRQ which then operates
the current regulator.
Very likely to be a hard-
ware error on the board
or in the processor.
Switch on the device
again (24V). If the error
appears again, the hard-
ware is faulty.
PS off