5
Service
18
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
4. tftp -i <ip-address> PUT <FILENAME.DCO>
<ip-address>
= IP address of the motor controller
<FILENAME.DCO>
= Filename of the parameter set
5. The PC copies the firmware file locally into the motor controller.
6. The motor controller checks the parameter set.
Parameter set is the same -> Parameter set is not loaded
Parameter set is different => Parameter set update is started.
7. The parameter set update is signaled through “d” on the digit representation with 7 segments.
8. The motor controller automatically starts the firmware by triggering a RESET.
During Parameter set download, error 49-0 may occur. Possible causes for this are:
–
Formatting error in the DCO file
–
Faulty parameters in the DCO file (invalid value).
–
Error during parameter access (read or write)
5.3.3
Save parameter set via Ethernet
A parameter set can be stored via the Ethernet interface [X18].
For computers that use Windows Vista or Windows 7 as operating system, the TFTP client and ports
must be specially activated or opened for the firewall.
Procedure with the program TFTP.EXE:
1. Make sure that the output stage enable is switched off.
2. Start the program CMD.EXE
3. Call up the program TFTP.EXE with the following syntax
4. tftp -i <ip-address> GET <FILENAME.DCO>
<ip-address>
= IP address of the motor controller
<FILENAME.DCO>
= Filename of the parameter set
5. Through the GET command, creation of the DCO file is started.
Creation of the DCO file takes approx. 1-2 seconds. Therefore, the first GET command is
answered with the error message “File not found”.
6. Enter the command “tftp -i <ip-address> GET <FILENAME.DCO>” again.
7. The motor controller copies the parameter set into the PC.
Summary of Contents for CMMP-AS-***-M3 Series