A
Diagnostic messages
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
83
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
02-0
3220
h
Undervoltage in
intermediate cir-
cuit
Intermediate circuit
voltage falls below the
parametrised threshold.
1)
Error priority set too
high?
•
Quick discharge due
to switched-off mains
supply.
•
Check power supply.
•
Couple intermediate
circuits if technically
permissible.
•
Check intermediate
circuit voltage (meas-
ure).
Config-
urable
03-0
4310
h
Analogue motor
overtemperature
Motor overloaded, tem-
perature too high.
–
Suitable sensor or
sensor characteristics
parametrised?
–
Sensor defective?
If there is overloading:
•
Check parameters
(current regulator,
current limits).
•
Check the paramet-
risation of the sensor
or the sensor charac-
teristics.
If the error persists when
the sensor is bypassed:
device defective.
QStop
03-1
4310
h
Digital motor
overtemperature
Motor overloaded, tem-
perature too high.
–
Suitable sensor or
sensor characteristics
parametrised?
–
Sensor defective?
If there is overloading:
•
Check parameters
(current regulator,
current limits).
•
Check the paramet-
risation of the sensor
or the sensor charac-
teristics.
If the error persists when
the sensor is bypassed:
device defective.
Config-
urable
03-2
4310
h
Analogue motor
overtemperature:
broken wire
The measured resistance
value is above the
threshold for wire break
detection.
•
Check the connecting
cables of the temper-
ature sensor for wire
breaks.
•
Check the paramet-
risation (threshold
value) for wire break
detection.
Config-
urable
1)
Supplemental information in PNU 203/213:
Top 16 bits:
Status number of internal state machine
Bottom 16 bits:
Intermediate circuit voltage (internal scaling approx. 17.1 digit/V).