![Festo CMMP-AS-***-M3 Series Description Download Page 40](http://html1.mh-extra.com/html/festo/cmmp-as-m3-series/cmmp-as-m3-series_description_2283123040.webp)
6
Functions
40
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
DIN8 (Start)
2
1
HA
MC
Speed
<>
0
DIG. HOLD
3
4
HA: HOMING_ACTIVE
MC: MOTION COMPLETE
1
0 … 10 ms
2
20 ms
3
Dependent on braking ramp
4
0 … 10 ms
Fig. 6.4
Timing diagram: homing with digital halt
6.3
Jog mode
6.3.1
Function
In the “Operation enabled” status, the drive can be travelled through jogging in a positive or negative
direction.
This function is usually used for:
–
Moving to teach positions
–
Drive free running (e.g. after a system malfunction)
–
Manual travel as a normal operating mode (manually operated feed).
The jog mode can be controlled as follows:
–
Fieldbus/FHPP (jog mode)
–
I/O interface through the parameterised digital inputs