Diagnostic messages
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
117
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
52-1
–
Safety module:
discrepancy time
expired
–
Control ports STO-A
and STO-B are not ac-
tuated simultan-
eously.
•
Check discrepancy
time.
PS off
–
Control ports STO-A
and STO-B are not
wired in the same way.
•
Check discrepancy
time.
52-2
–
Safety module:
driver supply fail-
ure with active
pulse-width mod-
ulation control
This error message does
not occur with equipment
delivered from the fact-
ory. It can occur with use
of a user-specific
CMMP-AS-...-M3 device
firmware.
•
The safe status was
requested with ap-
proved power end
stage. Check inclusion
in the safety-oriented
interface.
PS off
62-0
–
EtherCAT:
general bus error
No EtherCAT bus present.
•
Switch on the Ether-
CAT master.
•
Check wiring.
Config-
urable
62-1
–
EtherCAT:
Initialization error
Error in the hardware.
•
Replace the interface
and send it to the
manufacturer for
checking.
Config-
urable
62-2
–
EtherCAT:
CAN: Protocol er-
ror
CAN over EtherCAT is not
in use.
•
Incorrect protocol.
•
EtherCAT bus cabling
fault.
Config-
urable
62-3
–
EtherCAT:
Invalid RPDO
length
Sync manager 2 buffer
size is too large.
•
Check the RPDO con-
figuration of the mo-
tor controller and the
higher-level control
system.
Config-
urable
62-4
–
EtherCAT:
Invalid TPDO
length
Sync manager 3 buffer
size is too large.
•
Check the TPDO con-
figuration of the mo-
tor controller and the
higher-level control
system.
Config-
urable
62-5
–
EtherCAT:
Cyclic data trans-
mission error
Emergency shut-down
due to failure of cyclic
data transmission.
•
Check the configura-
tion of the master.
Synchronous trans-
mission is unstable.
Config-
urable