A
Diagnostic messages
124
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
83-0
–
Invalid option
module
–
The plugged-in inter-
face could not be de-
tected
–
The loaded firmware
is not known.
–
A supported interface
might be plugged into
the wrong slot (e.g.
SERCOS 2, EtherCAT).
•
Check firmware
whether interface is
supported. If yes,
•
Check that the inter-
face is in the right
place and is plugged
in correctly.
•
Replace interface
and/or firmware.
Config-
urable
83-1
–
Option module
not supported
The plugged-in interface
could be detected but is
not supported by the
loaded firmware.
•
Check firmware
whether interface is
supported.
•
If necessary, replace
the firmware.
Config-
urable
83-2
–
Option module:
hardware revision
not supported
The plugged-in interface
could be detected and is
basically also supported.
however in this case the
current hardware version
is not supported (be-
cause it is too old).
The interface must be ex-
changed. If necessary,
contact Technical Sup-
port.
Config-
urable
Summary of Contents for CMMP-AS-***-M3 Series