![Festo CMMP-AS-***-M3 Series Description Download Page 112](http://html1.mh-extra.com/html/festo/cmmp-as-m3-series/cmmp-as-m3-series_description_2283123112.webp)
A
Diagnostic messages
112
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
35-0
8480
h
Linear motor
spinning protec-
tion
Encoder signals are cor-
rupt. The motor may be
racing (“spinning”) be-
cause the commutation
position has been shifted
by the faulty encoder sig-
nals.
•
check that the install-
ation conforms to the
EMC recommenda-
tions.
•
In the case of linear
motors with induct-
ive/optical encoders
with separately moun-
ted measuring tape
and measuring head:
check the mechanical
clearance.
•
In the case of linear
motors with inductive
encoders, make sure
that the magnetic
field of the magnets or
the motor winding
does not leak into the
measuring head (this
effect usually occurs
when high accelera-
tions = high motor
current).
Config-
urable
36-0
6320
h
Parameter was
limited
An attempt was made to
write a value which was
outside the permitted
limits, so the value was
limited.
•
Check the user para-
meter record.
Config-
urable
36-1
6320
h
Parameter was
not accepted
An attempt was made to
write to an object which is
“read only” or is not
write-capable in the cur-
rent status (e.g. with con-
troller enable active).
•
Check the user para-
meter record.
Config-
urable
40-0
8612
h
Negative soft-
ware limit switch
The position setpoint has
reached or exceeded the
respective software limit
switch.
•
Check target data.
•
Check positioning
area.
Config-
urable
Summary of Contents for CMMP-AS-***-M3 Series