A
Diagnostic messages
122
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
72-3
–
PROFINET:
Invalid IP config-
uration
An invalid IP configuration
was entered in the inter-
face. The interface cannot
start with it.
Parameterise a permiss-
ible IP configuration via
FCT.
Config-
urable
72-4
–
PROFINET:
Invalid device
name
A PROFINET device name
was assigned with which
the controller cannot
communicate with the
PROFINET (character spe-
cification from PROFINET
standard).
Parameterise a permiss-
ible PROFINET device
name via FCT.
Config-
urable
72-5
–
PROFINET:
Interface defect-
ive
Interface CAMC-F-PN de-
fective.
Replace interface
Config-
urable
72-6
–
PROFINET:
Invalid/not sup-
ported indication
From the interface CAMC-
F-PN came a message
that is not supported by
the CMMP-AS-...-M3.
Please contact Technical
Support.
Config-
urable
73-0
–
PROFIenergy:
Status not pos-
sible
An attempt was made in a
positioning motion to
place the controller in the
energy-saving status. This
is only possible at rest.
The drive does not take
on the status and contin-
ues to travel.
–
Config-
urable
80-0
F080
h
Current regulator
IRQ overflow
The process data could
not be calculated in the
set current/velocity/posi-
tion interpolator cycle.
Please contact Technical
Support.
PS off
80-1
F081
h
Speed regulator
IRQ overflow
The process data could
not be calculated in the
set current/velocity/posi-
tion interpolator cycle.
Please contact Technical
Support.
PS off
Summary of Contents for CMMP-AS-***-M3 Series