A
Diagnostic messages
84
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
03-3
4310
h
Analogue motor
overtemperature:
short circuit
The measured resistance
value is below the
threshold for short circuit
detection.
•
Check the connecting
cables of the temper-
ature sensor for wire
breaks.
•
Check the paramet-
risation (threshold
value) for short circuit
detection.
Config-
urable
04-0
4210
h
Power end stage
overtemperature
Device is overheated
–
Temperature display
plausible?
–
Device fan defective?
–
Device overloaded?
•
Check installation
conditions; are the
control cabinet fan fil-
ters dirty?
•
Check the drive layout
(due to possible over-
loading in continuous
duty).
Config-
urable
04-1
4280
h
Intermediate cir-
cuit overtemper-
ature
Device is overheated
–
Temperature display
plausible?
–
Device fan defective?
–
Device overloaded?
•
Check installation
conditions; are the
control cabinet fan fil-
ters dirty?
•
Check the drive layout
(due to possible over-
loading in continuous
duty).
Config-
urable
05-5
–
Voltage failure in-
terface Ext1/Ext2
Defect on the plugged-in
interface
Interface replacement
Repair by the manu-
facturer.
PS off
05-6
–
Voltage failure
[X10], [X11]
Overloading through con-
nected peripherals
•
Check pin allocation
of the connected peri-
pherals.
•
Short circuit?
PS off
05-7
–
Safety module in-
ternal voltage
failure
Defect on the safety mod-
ule
Interface replacement
Repair by the manu-
facturer.
PS off
05-8
–
Failure of internal
voltage 3
Defect in the motor con-
troller
Internal defect
Repair
by the manufacturer.
PS off
Summary of Contents for CMMP-AS-***-M3 Series