A. Technical appendix
A-3
Festo P.BE-VIFB13-03-EN en 0003c
A.1
Technical data
General
Protection class
(as per EN
60529)
Temperature
during
– operation
– storage/transport
IP 65
- 5 °C ... +50 °C
-20 °C ... +60 °C
Vibration
(as per DIN/IEC68/EN 60068
Part 2-6 and as per IEC 721/EN
60068 Part 2-3)
– Transport
– Operation/Use
Shock
(as per DIN/IEC 68/EN 60068
Part 2-27 and IEC 721)
3.5 mm path at 2-8 Hz
1 g acceleration at 8-25 Hz
0.35 mm path at 25-57 Hz
5 g acceleration at 57-150 Hz
1 g acceleration at 150-200 Hz
30 g at 11 ms duration
Electromagnetic compatibility
(EMC)
Immunity against interference
– tested as per EN 50082-2
Interference emitted
– tested as per EN 50081-2
Industry
*)
Industry, limit value class A
*) The valve terminal with field bus node FB13-03/04-B can be used
with a special licence in residential areas (residential, business and
commercial areas, small businesses).
Protection against electric
shock
(Protection against di-
rect and indirect contact as per
EN 60204-1/IEC 204)
by PELV power unit (Protected
Extra Low Voltage)
Summary of Contents for 174335
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE VIFB13 03 EN en 0003c...
Page 17: ...Summary of components 1 1 Festo P BE VIFB13 03 EN en 0003c Chapter 1...
Page 26: ...1 Summary of components 1 10 Festo P BE VIFB13 03 EN en 0003c...
Page 27: ...Fitting 2 1 Festo P BE VIFB13 03 EN en 0003c Chapter 2...
Page 37: ...Installation 3 1 Festo P BE VIFB13 03 EN en 0003c Chapter 3...
Page 66: ...3 Installation 3 30 Festo P BE VIFB13 03 EN en 0003c...
Page 67: ...Commissioning 4 1 Festo P BE VIFB13 03 EN en 0003c Chapter 4...
Page 123: ...Diagnosis and error treatment 5 1 Festo P BE VIFB13 03 EN en 0003c Chapter 5...
Page 162: ...5 Diagnosis and error treatment 5 40 Festo P BE VIFB13 03 EN en 0003c...
Page 163: ...Technical appendix A 1 Festo P BE VIFB13 03 EN en 0003c Appendix A...
Page 177: ...Index B 1 Festo P BE VIFB13 03 EN en 0003c Appendix B...
Page 178: ...B Index B 2 Festo P BE VIFB13 03 EN en 0003c...