5. Diagnosis and error treatment
5-16
Festo P.BE-VIFB13-03-EN en 0003c
The 4 status bits provide coded diagnostic information with
the following significance:
Status bits*)
Diagnostic information
2
7
2
6
2
5
2
4
0
0
0
0
no error
X
0
1
X
Short circuit/overload at output
X
1
0
X
V
valves
<
21.6V**)
X
1
1
X
V
outputs
<
10V**)
1
X
X
X
V
Sensor
<
10 V
X
X
X
1
A error bit (AS-i/Analog I/O)
X = not relevant
*) The status bits can always be addressed at the four highest value addresses of the configured
address space.
**) only when the voltage monitoring is activated (see Chapter 3.2.3, DIL switch)
Fig. 5/10: Coded diagnostic information of the 4 status bits
Summary of Contents for 174335
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE VIFB13 03 EN en 0003c...
Page 17: ...Summary of components 1 1 Festo P BE VIFB13 03 EN en 0003c Chapter 1...
Page 26: ...1 Summary of components 1 10 Festo P BE VIFB13 03 EN en 0003c...
Page 27: ...Fitting 2 1 Festo P BE VIFB13 03 EN en 0003c Chapter 2...
Page 37: ...Installation 3 1 Festo P BE VIFB13 03 EN en 0003c Chapter 3...
Page 66: ...3 Installation 3 30 Festo P BE VIFB13 03 EN en 0003c...
Page 67: ...Commissioning 4 1 Festo P BE VIFB13 03 EN en 0003c Chapter 4...
Page 123: ...Diagnosis and error treatment 5 1 Festo P BE VIFB13 03 EN en 0003c Chapter 5...
Page 162: ...5 Diagnosis and error treatment 5 40 Festo P BE VIFB13 03 EN en 0003c...
Page 163: ...Technical appendix A 1 Festo P BE VIFB13 03 EN en 0003c Appendix A...
Page 177: ...Index B 1 Festo P BE VIFB13 03 EN en 0003c Appendix B...
Page 178: ...B Index B 2 Festo P BE VIFB13 03 EN en 0003c...