![Festo 174335 Electronic Manual Download Page 72](http://html1.mh-extra.com/html/festo/174335/174335_electronic-manual_2284126072.webp)
4. Commissioning
4-6
Festo P.BE-VIFB13-03-EN en 0003c
4.1.2 Address assignment of the valve terminal
The address assignment of the outputs of a multifunctional
valve terminal depends on the equipment fitted on the valve
terminal. A distinction is made between the following equip-
ment fitted:
–
valves and digital I/O modules.
–
only valves.
–
only digital I/O modules.
The basic rules described below apply to the address assign-
ment of these fitting variants. A detailed example is given
after each of these basic rules.
Please note
If two addresses are assigned for one valve location, the
following assignment applies:
– lower-value address:
pilot solenoid 14
– higher-value address:
pilot solenoid 12
Information on reserving addresses of the valves on the type
04-B valve terminal can be found in the Pneumatics manual
for type 04-B.
Summary of Contents for 174335
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE VIFB13 03 EN en 0003c...
Page 17: ...Summary of components 1 1 Festo P BE VIFB13 03 EN en 0003c Chapter 1...
Page 26: ...1 Summary of components 1 10 Festo P BE VIFB13 03 EN en 0003c...
Page 27: ...Fitting 2 1 Festo P BE VIFB13 03 EN en 0003c Chapter 2...
Page 37: ...Installation 3 1 Festo P BE VIFB13 03 EN en 0003c Chapter 3...
Page 66: ...3 Installation 3 30 Festo P BE VIFB13 03 EN en 0003c...
Page 67: ...Commissioning 4 1 Festo P BE VIFB13 03 EN en 0003c Chapter 4...
Page 123: ...Diagnosis and error treatment 5 1 Festo P BE VIFB13 03 EN en 0003c Chapter 5...
Page 162: ...5 Diagnosis and error treatment 5 40 Festo P BE VIFB13 03 EN en 0003c...
Page 163: ...Technical appendix A 1 Festo P BE VIFB13 03 EN en 0003c Appendix A...
Page 177: ...Index B 1 Festo P BE VIFB13 03 EN en 0003c Appendix B...
Page 178: ...B Index B 2 Festo P BE VIFB13 03 EN en 0003c...