![background image](http://html2.mh-extra.com/html/feig-electronic/id-isc-ant1710-690-crystal-gate-excellence/id-isc-ant1710-690-crystal-gate-excellence_installation-manual_3878650024.webp)
IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Excellence -A/-B
Typical Antenna Configuration
Page 22 of 22
1.1 W – 2.0 W
3 m
> 2 W
4 m
>= 4 W
8 m
Table 4: Minimum Distances
•
The reader must not be disturbed by other electrical devices in the environment. The difference in noise
level should be less than 20 mV.
•
The ID ISC.LRM2500 reader should be set to an RF power of 4 watts.
•
When using ISO 15693 transponders, the readers should be set as described in 7.3.6 Reader
Configuration with Multiplexer
•
If multiple gates are operated at the same time at a distance of less than 8 m, the readers must be
synchronized. See Application Note
Synchronizing RFID Long Range Readers using the digital in-
/outputs
(N10311-xe-ID-B.pdf).
Gate with antenna
Type A and Type B
Gate distance GD
≤
100 cm
Number of tags at a speed of 1 m/s
Read serial number
Read data
16
8
Table 5: Gate distance
Supplementary equipment (e.g. light barrier, lighting, etc.), mounted directly on the antenna or in the
immediate vicinity of the antenna can interfere with the function of the system.
A minimum distance of 20 cm is required.
Electrical cables, directly at the antenna or in the immediate vicinity of the antenna, can cause interference.
A minimum distance of 20 cm is required.
A minimum distance of 65 cm between the two gate antennas is required.