8.3.2 Configuration and Test in ISO Host Mode or Buffered Read Mode
Step
Action
Note
1
Select „Configuration“
2
Host Interface
Set RS 485 to “False” and
„Enable Termination Resistors“
The RS232/485 Settings should
be set to:
Busaddress=0, Baudrate=38400
baud, Parity = even ,
Number of Databits = 8, Number
of Stopbits = 1
3
Confirm with „Apply“
4
Peripheral Devices
Gate People Counter
Set Antenna Type “HPDx”
Mode
Enable GPC to
„New Generation”
5
Confirm with „Apply“
6
Peripheral Device
LED Controller:
Setting Time:
„Setting Time“ set the duration
time for the alarm.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign
LED Bus Address 11 to antenna
1-4.
LED Bus Address 12 to antenna
1-4.
......... and so on.
„True“ means: LED with Bus
Address 11, 12, 13, 14 will be
active if the reader read a valid
transponder on the
corresponding antenna
7
Set by clicking on „Apply“.