8.3 Configuration and Test
To activate the people counter the following settings have to be made.
In addition, set the jumpers JP10 and J11 of the reader ID ISC.LRM2500-B to configure the RS485 interface
(see also Manual M81010-xe-ID-B, page 19 and 20). The Termination must be activated via software in the
reader configuration.
Fig. 28: Jumper settings RS485 Interface
8.3.1 Connecting Several People Counters
When using several people counters (up to 3) on one reader, you must connect the terminal boards of all
antennas used in parallel. A 5 (6) pin shielded, twisted-pair cable must be used for connection. Example:
LiYCY (TP) 3x2x0,25 . The cable is content of antenna Type B
The bus address of the people counter will be defined by the antenna number it is installed in.
GPC1 in Antenna No.1 = Bus address No. 1
GPC2 in antenna No.4 = Bus address No. 2
The bus address is automatically set after the complete gate has been set up and configured and a [0x64]
System Reset command in one of the Reader Automatic Modes has been executed.
See also 7.7 Automatic Bus Addressing. The successful detection of the connected Gate People Counter
can be checked with command [0x66] Get Reader Info.
The number of detected GPC and its firmware version is also shown on the LCD display after a power-up or
the command [0x64] System Reset.
J11
VCC
J10
500
Ω
500
Ω
RS485 +
RS485 -