![background image](http://html2.mh-extra.com/html/feig-electronic/id-isc-ant1710-690-crystal-gate-excellence/id-isc-ant1710-690-crystal-gate-excellence_installation-manual_3878650027.webp)
IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Excellence -A/-B
Typical Antenna Configuration
Page 25 of 25
Cross traffic in the detection area, i.e. people who cross in front of the antennas, go from left to right (or
contrariwise), can also be counted or recorded.
To avoid interference, the detection area of radar motion detector mounted above or at automatic doors
(operating frequency 24.125 GHz) must not overlap with the detection area of the people counter.
NOTE:
•
The People Counter is designed to obtain statistical values on visitor flows. For persons with
small distances, due to interferences and cross traffic, the determined values of the actual values
can vary.
•
If major deviations are noticed, first the sensitivity of the radar sensors should be gradually
reduced.
7.3 Gate Configuration and Setup Using Antennas
7.3.1 Required Components
To set up the gate you need the following components:
•
1 ID ISC.ANT1710/690-A Crystal Gate Excellence (Base)
(incl. 1 ID ISC.NET24V-B Power Supply Unit)
•
1 ID ISC. ANT1710/690-B Crystal Gate Excellence
•
power cable, interface cable and connection cable for the DC power supply (2-wire, twisted)
•
mounting materials (screws, anchors)
To calibrate the reader, you need the software
•
ISOStart 2019 Version 10.xx.xx or higher
and for tuning the antennas the service software
•
DATuningTool Version 1.02.02 or higher
on a computer running Microsoft® Windows®. The software can be downloaded from the download area at
www.feig.de.