background image

Operating instructions TSM-21 

 

 

 
 

 

Status as of 12 / 2021 

Page 1 

 
 

  Operating instructions 

       

 

       

 

       

 

       

 

       

 

       

 

       

 

       

 

    TSM-21 hopper call-up control 
    for belt hoppers of type BB / BZS

 

    Art. no.: 90.0010.60  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

    fimotec-fischer GmbH & Co. KG 
  Friedhofstraße 

13 

    D -78588 Denkingen 

 

    Tel:     +49 (0)74 24 - 88 4-0 
    Fax:    +49 (0)74 24 - 88 4-50 

 

  E-mail: 

 [email protected] 

    Internet:  www.fimotec.de                                          

Summary of Contents for 90.0010.60

Page 1: ... Operating instructions TSM 21 hopper call up control for belt hoppers of type BB BZS Art no 90 0010 60 fimotec fischer GmbH Co KG Friedhofstraße 13 D 78588 Denkingen Tel 49 0 74 24 88 4 0 Fax 49 0 74 24 88 4 50 E mail post fimotec de Internet www fimotec de ...

Page 2: ...Tel 49 7424 884 0 Fax 49 7424 884 50 E Mail post fimotec de Web wwwfimotec de Provisos The information and data contained in these documents can be changed without advance notification Users are obligated to comply with all applicable copyright laws No part of these documents can be duplicated or transmitted without the express written permission from fimotec fischer GmbH Co KG independent of how ...

Page 3: ...ntended use 6 2 Installation 7 2 1 Overview and dimensions 8 2 2 Connections operating elements of boards 9 2 3 Housing connections 10 3 Commissioning 11 3 1 Hopper belt operation 11 3 2 Hopper filling level check operation 13 4 Technical data 14 5 Error list 14 6 Maintenance and cleaning 15 7 Disposal 15 8 CE conformity 15 9 Service 15 10 Accessories not included in the scope of delivery 16 ...

Page 4: ... and trimmers All connections are designed to be pluggable 2 transistor outputs 24V are available malfunction hopper filling level 2 sensor inputs are available filling level of feeding device level sensor and hopper filling level 1 control input is available control disable 1 2 Guide for these instructions Used signal words and symbols Symbol Signal word Meaning Danger Warning of potentially seri...

Page 5: ...revention and safety regulations for your specific application Before commissioning check whether the nominal voltage of the device agrees with the local mains voltage Emergency Stop mechanisms must remain active in all operating modes Unlocking the Emergency Stop mechanisms must not result in uncontrolled reactivation The electrical connections must be covered Protective conductor connections mus...

Page 6: ...g For applications requiring constant switching ON and OFF the control input provided for this must be used If the load current circuit is interrupted via a switch or relay the control device could be damaged If the device is switched on the device plug must never be plugged in or unplugged The control device could be damaged 1 4 Intended use The device described here is an electrical piece of equ...

Page 7: ... the device to a vibration free surface Important note Fasten to a vibration free surface Caution Please make sure that the cable is not pinched against the housing in the interior Pinching can cause a short circuit and result in destruction of the device Warning Procedure for high voltage test L and N must be connected with each other Test voltage may not be higher than 1000 V AC Every device mus...

Page 8: ...2 1 Overview and dimensions A Reset button Acknowledge malfunction B Mains switch illuminated C X24 Filling level sensor workpiece shortage D X21 Controller disable S Mains feed F Load output with Hirschmann plug GDM 3016 G X22 Level sensor malfunction message ...

Page 9: ...T button cover Terminal 10 X22 Level sensor Terminal 11 X24 Filling level sensor Terminal 12 X24 24 V Terminal 13 X24 Lack of workpieces Terminal 14 X24 GND Terminal 15 X22 24 V Terminal 16 X22 Malfunction message Terminal 17 X22 GND SI 1 Control electronics 400 mA slow blow SI 2 Load 3 15 A slow blow DIP 5 Configuration settings P1 Hopper filling level toff 0 20 s P2 Hopper filling level ton 0 20...

Page 10: ...PE PE X22 Malfunction message level sensor connection Pin 1 24 V Pin 2 Malfunction message formerly X23 Pin 3 GND Pin 4 Level sensor formerly X22 X21 Controller disable connection Pin 1 24 V Pin 2 Not connected Pin 3 GND Pin 4 Controller disable formerly X21 X24 Workpiece shortage filling level sensor connection Pin 1 24 V Pin 2 Workpiece shortage formerly X26 Pin 3 GND Pin 4 Filling level sensor ...

Page 11: ...this can result in a failure or in the complete destruction of the device and the connected load 3 1 Hopper belt operation General The workpiece in the area around the vibration bowl is detected via a sensor If no workpiece is detected by the sensor the hopper control switches the drive on for the hopper belt Various functions are available for the drive Setting via Function Description Drive mode...

Page 12: ...d The drive runs until the level sensor detects a workpiece and switches off the drive Drive runs cyclically The level sensor does not detect a workpiece in the subsequent machine and switches the drive on after the time tbelt has elapsed Switch on time drive 1 0 s or 2 5 s pause time tpause 0 5 15 s Malfunction After the switch on delay tbelt has elapsed the switch on delay malfunction tmalfuncti...

Page 13: ...nverted DIP 5 OFF Sensor input signal N O not inverted Switch on delay ton Trimmer P2 Switch on delay filling level 0 20 s Switch off delay toff Trimmer P1 Switch off delay filling level 0 20 s Switch on delay The filling level in the hopper is monitored with a light barrier If a lack of workpieces is detected by the sensor the switch on delay ton starts After this time elapses the lack of workpie...

Page 14: ...evel LO 0 4V Malfunction O 24 V max 100 mA Lack of workpieces A 24 V max 50 mA Housing ABS Housing dimensions h 120 x b 122 x t 55 mm Operating temperature 5 45 C Relative humidity Max 95 non condensing 5 Error list Danger Life threatening danger due to electric current Have repairs to the 230 V power network performed only by a qualified professional Problem error Possible cause s Remedy Device d...

Page 15: ...facility 8 CE conformity The motor control device TSM 21 is marked with the CE marking and therefore meets the relevant European directives The company fimotec fischer GmbH Co KG herewith confirms that this device complies with the following directives EN 61000 6 3 and EN 61000 6 2 according to EU directive 2014 30 EU Electromagnetic compatibility The declaration of conformity is archived at the m...

Page 16: ...g level M8 4p 3m angled St M12 FFM_91 4214 05 Connection cable Filling level M8 4p 5m straight St M12 FFM_91 4214 06 Connection cable Filling level M8 4p 5m angled St M12 FFM_91 4214 07 Connection cable Filling level M12 3m straight St M12 FFM_91 4214 08 Connection cable Filling level M12 3m angled St M12 FFM_91 4214 09 Connection cable Filling level M12 5m straight St M12 FFM_91 4214 10 Connectio...

Reviews: