8.3.5 Using the Direction Detection of Transponders with the Gate People Counter
In combination with the people counter, direction detection of the transponders can be performed in such
way that only those transponders trigger an alarm that move through the gate in the configured direction.
This should reduce false alarms. It is possible that cross traffic in front of the antenna can still cause false
alarms, if a valid transponder moves in the set direction.
It is mandatory that the trigger cable described in 8.3.4 Using the Trigger Function of the Gate People
Counter is connected to input 2 of the reader and X4/TRG of the terminal board, otherwise the direction
mode will not work!
Step
Action
Note
1
Select „Configuration“
2
Select Peripheral Devices –
Gate People Counter
Set Direction Mode to the needed
alarm direction.
Select Perhiperal Devices -
Filter
Set Time Limit before and after
Tag Detection.
e.g. 200x5ms =1000ms
Time should be not to
short or to long!
3
Confirm with „Apply“
7
Walk through the gate with a valid
transponder and check the alarm
direction.
If there are multiple gates with more than two antennas, the correct number order of the connected
antennas, alarm LEDs and people counters with radar module must be observed. For information on setup,
connection and configuration, refer to Application Note N71100-xe-ID-E.pdf.