A cable opening is provided for the necessary connection cable (see Fig. 6). The cable opening is
dimensioned so that up to 10 cables with a diameter of 6 mm can be led through the opening.
Alternatively, the cables can be routed at the sides of the antenna foot, as shown in
Fig. 7.
Fig. 7 Cable routing at the antenna sides
6.2.3 Installing the Antenna Base and Antenna Body
The antenna is mounted on the floor. Please note that the antenna conductors in the middle of the antenna
body must have the same direction (
Fig. 8). Afterwards, the antenna must be aligned vertically, by using the adjusting screws (Fig. 9). Please
read 8.3.4 Using the Trigger Function of the Gate People Counter and 7.2 Project Notes People Counter
(GPC).
Fig. 8 The shape of the conductors must have the same direction
Adjusting screws (hexagon socket width AF 4)