IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Excellence -A/-B
Typical Antenna Configuration
Page 48 of 48
7.6 Activating a Reader Automatic Mode
Which mode is most suitable for your application must be defined in advance.
This example describes how to activate the Buffered Read Mode.
In the Reader Automatic Modes, the tags are read at maximum speed and the information is stored in the
reader’s ring buffer. The data set can be read by the host.
Due to the automatic alarm functions in the automatic mode, the reader/gate can also be operated without
any interface connection (Serial, Ethernet).
To activate the Buffered Read Mode, proceed as follows:
Step
Action
Note
1
Select „Configuration“
2
Operation Mode:
„Mode“ - Buffered Read Mode
„Data Selector“
-UID
-Antenna No
-Time
-Date
„Filter“
Set Transponder Valid Time.
(e.g. 55 x 100ms)
3
Set clicking on „Apply“
NOTE:
•
The gate has to be used in one of the Automatic Modes (Buffered Read, Notification or Scan
Mode) to get a maximum performance. Otherwise the reading performance will be significantly
reduced.
•
The configuration of the Notification Mode or Scan Mode are similar (see Manual of the reader).
To test the function of the gate in the Buffered Read Mode, the BRM window of ISOStart can be
used.
For more information, refer to Manual H01112-2e-ID-B.pdf ID ISC.LRM2500-A/B