![Fanotec MECHA C2 User Manual Download Page 62](http://html.mh-extra.com/html/fanotec/mecha-c2/mecha-c2_user-manual_542544062.webp)
62
MECHA C2 User’s Guide
v.02.5
© 2021 FANOTEC
Power OFF after
— If this field is not empty, then the value specified here
tells MECHA to power off if there is no activity a number of seconds equal
to this value.
The second
Power OFF after
field — The same as the first field, but it refers
to the period of time immediately after powering on MECHA, when no
presets are executed. Value 1 means
No Power OFF.
Rotator Settings
If you use only one rotator, fill in the fields for rotator 2 with the data for
rotator 1.
Rotator 1
— Set the
lower
rotator in use by selecting an option from the
list, or using the following codes:
13131<
for E1,
13132<
for E2, and
13121<
for P1. The
AUTO
option enables the automatic detection of the rotator type
for the lower rotator.
Inverted
— Check this checkbox if, for a particular reason, the rotator needs
to have all its movements in the opposite sense of rotation, for example
when mounted under a turn table.
Backlash 1
— If the value needs to be entered manually instead of using the
automatic procedure, for E1 and E2 rotators it is around 21, and for P1
rotator the value is 0 (zero). It is recommended to use the automatic